George Products Company, Inc.

Sunday, May 19, 2013
OASIS Elite > Accuracy Testing

Accuracy Testing

 

Accuracy testing was performed by using the OASIS to measure the diameter of 0.3750" dia gage pins. The testing was performed using 10 Parts, 3 Trials, and 3 Operators. The Parts and Operators were sequenced in random order.

 

Following are the results of the testing:

  • Accuracy = 0.0001" (2.54 microns)
  • Repeatability = 0.0001" (2.54 microns)
  • Reproducibility = 0.00004" (1.02 microns)
  • Resolution = 0.0001" (2.54 microns)

NOTE: These are total values, NOT +/- values.

 

 

Gage R&R

 

Based on a tolerance of +/-0.001", Gage R&R is as follows:

Part Variation = 1.2 %
Equipment Variation = 5.0 %
Appraiser Variation = 1.9 %
GRR = 5.4 %

 

 

Gage R&R Report

 

 

Click here to download the Gage R&R Report in .PDF file format.

 

Click here to download a spreadsheet of the raw test data.